Difference between revisions of "Talk:BaSyx / Documentation / API / ControlComponent"

m (Small improvements to the description.)
m (Added OPERATIONS and STATUS as own lines in the table. Added example figure for OPC UA.)
Line 39: Line 39:
 
! Corresponding state machine
 
! Corresponding state machine
 
! Description
 
! Description
 +
|-
 +
| STATUS
 +
|
 +
| Property group for all status properties
 
|-
 
|-
 
| STATUS/OCCST
 
| STATUS/OCCST
Line 71: Line 75:
 
! Corresponding state machine
 
! Corresponding state machine
 
! Description
 
! Description
 +
|-
 +
| OPERATIONS
 +
|
 +
| Group for all operations
 
|-
 
|-
 
| OPERATIONS/FREE
 
| OPERATIONS/FREE
Line 117: Line 125:
  
 
The BaSys 4.0 project has defined technology mappings for the device interface that are implemented by the Virtual Automation bus. BaSyx users may define additional technology mappings for other types of networks and bus systems, and include them by creating BaSyx Virtual Automation Bus (VAB) Gateways.
 
The BaSys 4.0 project has defined technology mappings for the device interface that are implemented by the Virtual Automation bus. BaSyx users may define additional technology mappings for other types of networks and bus systems, and include them by creating BaSyx Virtual Automation Bus (VAB) Gateways.
 
  
 
==== OPC-UA ====
 
==== OPC-UA ====
  
This section defines a mapping of the BaSys 4.0 control component interface to OPC-UA. Our OPC-UA mapping maps VAB operations to OPC-UA methods and VAB attributes to OPC-UA variables, resprectively properties. Eclipse BaSyx will provide a generic BaSyx OPC-UA gateway component to connect control components with the OPC-UA interface from this section to the virtual automation bus and therefore enables accessing of the control component status and services. Developers therefore only need to implement this OPC-UA object structure to ensure a BaSyx conforming component. The control components browsename itself is not relevant as it is identified by its node id corresponding to the VAB elementId. The namespace index of all browse names should be the basys namespace ''basys40.de''.
+
[[File:BaSyx-ControlComponent-OPCUA-BaSysProfile.png|thumb|An example control component in OPC UA realizing the BASYS profile. The control components address space is marked in orange.]]
 +
This section defines a mapping of the BaSys 4.0 control component interface to OPC-UA. Our OPC-UA mapping maps VAB operations to OPC-UA methods and VAB attributes to OPC-UA variables, resprectively properties. Eclipse BaSyx will provide a generic BaSyx OPC-UA gateway component to connect control components with the OPC-UA interface from this section to the virtual automation bus and therefore enables accessing of the control component status and services. Developers therefore only need to implement this OPC-UA object structure to ensure a BaSyx conforming component. The control components browsename itself is not relevant as it is identified by its node id corresponding to the VAB elementId, shown in green in the [[:File:BaSyx-ControlComponent-OPCUA-BaSysProfile.png|example figure]]. The namespace index of all browse names defined here, should be the basys namespace ''basys40.de'', which is namespace 2 in the [[:File:BaSyx-ControlComponent-OPCUA-BaSysProfile.png|example figure]]. Operations to select application or domain specific operation modes should be written in CamelCase and should use own namespaces or the application namespace.
 +
For the interface only the minimum required characteristics are describe in order to gain as much freedom of implementation as possible (cf. [[BaSyx_/_Documentation_/_ControlComponentProfiles#Interface_Specification|interface specification]]).
 +
Hence only the entry point (VAB elementId, OPC UA node id of the control component) and browsepathes are specified, as shown in the blue field in the [[:File:BaSyx-ControlComponent-OPCUA-BaSysProfile.png|example figure]].
 +
For example no display names, descriptions, node ids, type references or reference types for the hierarchical references are specified.
  
 
{| class="wikitable"
 
{| class="wikitable"
Line 127: Line 138:
 
! Node class
 
! Node class
 
! Data type  
 
! Data type  
 +
|-
 +
| STATUS
 +
| Object or Variable
 +
| Group for all status variables
 
|-
 
|-
 
| STATUS/OCCST
 
| STATUS/OCCST
Line 155: Line 170:
 
| Variable
 
| Variable
 
| String
 
| String
 +
|-
 +
| OPERATIONS
 +
| Object or Variable
 +
| Group for all operations
 
|-
 
|-
 
| OPERATIONS/FREE
 
| OPERATIONS/FREE

Revision as of 06:02, 17 March 2020

Control component interface harmonization

Lets try to harmonize existing implementations of control components and sync to the control component profiles, which are used to test conformance. The following changes to the VAB implmentation documentation of control components are suggested:

  • Only define a 'default' BaSyx VAB implementation (not 'minimum' required) as different requirements apply for different use cases.
  • Delete 'service' path segment for list of operations.
  • Use uppercase paths to distinguish between user specific and standardized elements.
  • Focus on the OPERATIONS service interface.
  • Focus on 'mandatory' attributes.
  • Delete BSTATE as mandatory operation mode.
  • Delete signals for localOverwrite and localOverwriteFree as they are technology specific and should be 'hard wired'.
  • Use network layer authorization to occupy component (no senderId parameter for operations, otherwise all operations need a senderId parameter).
  • OPC UA mapping:
    • Delete Control path segment for the OPC UA browse path
    • Add a namespace for basys that can be used to translate the browsepath and to for companion specifications later: basys40.de
  • Which facets should form the BASYS profile?
    • Possible:
      • SI: CMD, OPERATIONS, SERVICES
      • OC: NONE, OCCUPIED, PRIO
      • EM: NONE, AUTO, SEMIAUTO, MANUAL, SIMULATE
      • ES: Minimum / full PackML
      • OM: NONE / MULTI /PARALLEL
    • Suggested:
      • SI: OPERATIONS
      • OC: OCCUPIED, PRIO
      • EM: AUTO, MANUAL
      • ES: Minimum PackML (START, STOP, RESET, ABORT and corresponding states)
      • OM: MULTI

The following sections are adapted to the suggested changes above.

Virtual Automation Bus (VAB) implementation

Eclipse BaSyx connects BaSyx control components as elements to the Virtual Automation Bus (VAB), the End-to-End communication infrastructure of Eclipse BaSyx. Every BaSyx control component needs to implement the minimum VAB interface that is described in this section. The following table illustrates the minimum set of VAB attributes and operations for control components that are connected to the virtual automation bus. The predefined property group STATUS lists all propertys describing the current status of the control component, respectively its state machine states. The predefined OPERATIONS group implement the minimum API for every control component that enables the control of its states via the previously described state machines.

Attribute path (output) Corresponding state machine Description
STATUS Property group for all status properties
STATUS/OCCST Occupation Current occupation state
STATUS/OCCUPIER Occupation ID of current occupier
STATUS/EXMODE Execution mode Active execution mode
STATUS/EXST Execution state Active execution state
STATUS/OPMODE Operation mode Active operation mode
STATUS/WORKST Work state Current work state
STATUS/ER Error state Current error state
Operations Corresponding state machine Description
OPERATIONS Group for all operations
OPERATIONS/FREE Occupation Free component occupation if sender is occupier
OPERATIONS/OCCUPY Occupation Occupy component
OPERATIONS/PRIO Occupation Occupy component with priority
OPERATIONS/AUTO Execution mode Change to execution mode AUTO
OPERATIONS/MANUAL Execution mode Change to execution mode MANUAL
OPERATIONS/START Execution mode Start selected operation mode
OPERATIONS/RESET Execution mode Reset completed or stopped control component
OPERATIONS/ABORT Execution mode Abort operation
OPERATIONS/STOP Execution mode Stop operation
OPERATIONS/CLEAR Execution mode Clear aborted execution state


Technology mappings

The BaSys 4.0 project has defined technology mappings for the device interface that are implemented by the Virtual Automation bus. BaSyx users may define additional technology mappings for other types of networks and bus systems, and include them by creating BaSyx Virtual Automation Bus (VAB) Gateways.

OPC-UA

An example control component in OPC UA realizing the BASYS profile. The control components address space is marked in orange.

This section defines a mapping of the BaSys 4.0 control component interface to OPC-UA. Our OPC-UA mapping maps VAB operations to OPC-UA methods and VAB attributes to OPC-UA variables, resprectively properties. Eclipse BaSyx will provide a generic BaSyx OPC-UA gateway component to connect control components with the OPC-UA interface from this section to the virtual automation bus and therefore enables accessing of the control component status and services. Developers therefore only need to implement this OPC-UA object structure to ensure a BaSyx conforming component. The control components browsename itself is not relevant as it is identified by its node id corresponding to the VAB elementId, shown in green in the example figure. The namespace index of all browse names defined here, should be the basys namespace basys40.de, which is namespace 2 in the example figure. Operations to select application or domain specific operation modes should be written in CamelCase and should use own namespaces or the application namespace. For the interface only the minimum required characteristics are describe in order to gain as much freedom of implementation as possible (cf. interface specification). Hence only the entry point (VAB elementId, OPC UA node id of the control component) and browsepathes are specified, as shown in the blue field in the example figure. For example no display names, descriptions, node ids, type references or reference types for the hierarchical references are specified.

Relative OPC-UA browse path Node class Data type
STATUS Object or Variable Group for all status variables
STATUS/OCCST Variable String
STATUS/OCCUPIER Variable String
STATUS/EXMODE Variable String
STATUS/EXST Variable String
STATUS/OPMODE Variable String
STATUS/WORKST Variable String
STATUS/ER Variable String
OPERATIONS Object or Variable Group for all operations
OPERATIONS/FREE Method
OPERATIONS/OCCUPY Method
OPERATIONS/PRIO Method
OPERATIONS/AUTO Method
OPERATIONS/MANUAL Method
OPERATIONS/START Method
OPERATIONS/RESET Method
OPERATIONS/ABORT Method
OPERATIONS/STOP Method
OPERATIONS/CLEAR Method

Additional gateways may implement additional mapping schemes, and may include control components and devices with non-conforming interfaces by implementing component and device specific mappings that provide a conforming façade to the VAB.