Skip to main content

Notice: this Wiki will be going read only early in 2024 and edits will no longer be possible. Please see: https://gitlab.eclipse.org/eclipsefdn/helpdesk/-/wikis/Wiki-shutdown-plan for the plan.

Jump to: navigation, search

BaSyx / Documentation / Components / DataBridge / Features / AAS Endpoint

AAS Data Sink

The AAS Server can be integrated with DataBridge. The AAS component can be configured as a Data Sink in the DataBridge.

Configuration

To configure AAS Server in DataBridge you need to provide the unique id, endpoint of the Submodel, idShort path and the api type. The AAS endpoint supports both the Dot AAS V1 (BaSyx) as well as Dot AAS V3 (DotAAS-V3) specifications api.

Sample Configuration Dot AAS V1

[
	{
		"uniqueId": "ConnectedSubmodel/ConnectedPropertyA",
		"submodelEndpoint": "http://localhost:4001/shells/TestUpdatedDeviceAAS/aas/submodels/ConnectedSubmodel/submodel",
		"idShortPath": "ConnectedPropertyA",
                "api": "BaSyx"
	}
]

Sample Configuration Dot AAS V3

[
	{
		"uniqueId": "ConnectedTestSubmodel/DotAASV3ConformantApiSMC/DotAASV3ConformantApiProperty",
		"submodelEndpoint": "http://localhost:4001/submodels/c3VibW9kZWxJZA==",
		"idShortPath": "DotAASV3ConformantApiSMC.DotAASV3ConformantApiProperty",
		"api": "DotAAS-V3"
	}
]

In the submodelEndpoint, the c3VibW9kZWxJZA== is the Base64 encoded identifier of the Submodel. As per the DotAAS-V3 specification the idShortPath should be dot-separated as shown in the configuration above.

Note: The default api type is Dot AAS V1 (BaSyx).

Similarly, you can configure multiple AAS sinks inside the configuration file.

Naming Convention

The name of the AAS configuration file should be aasserver.json.

Working Example

The integration example with MQTT as a data source, JSONata as a transformer, and AAS as a data sink is on GitHub DataBridge Example.

Back to the top